Dell PowerEdge Operate 2023 D-PE-OE-23 Exam Questions

  Edina  01-16-2024

D-PE-OE-23 Dell PowerEdge Operate 2023 Exam is the new version of the retired DES-4122 exam. PassQuestion understands the importance of thorough preparation for the D-PE-OE-23 exam, which is why we offer a comprehensive collection of Dell PowerEdge Operate 2023 D-PE-OE-23 Exam Questions. Our extensive range of questions covers all the exam objectives, ensuring that you have all the resources necessary to successfully pass your exam with confidence and ease. By following these comprehensive Dell PowerEdge Operate 2023 D-PE-OE-23 Exam Questions, you can significantly enhance your chances of success in the D-PE-OE-23 Dell PowerEdge Operate 2023 Exam.

D-PE-OE-23 Exam Overview - Dell PowerEdge Operate 2023 Exam

This exam is designed to assess the proficiency in executing a wide range of intermediate skill level tasks related to the implementation, configuration, upgrading, maintenance, and troubleshooting of Dell PowerEdge Server products. By successfully completing this exam, candidates demonstrate their comprehensive understanding and practical application of these essential skills. This D-PE-OE-23 exam contains two parts. You should pass both part 1 and part 2 to get this Dell PowerEdge Operate 2023 exam.

Part 1:
The first part of the exam spans a duration of 90 minutes and consists of a total of 50 questions. These questions cover various aspects of Dell PowerEdge Server products and require candidates to showcase their knowledge and problem-solving abilities. To pass this section, candidates need to achieve a minimum score of 63%.

Part 2:
The second part of the exam is a simulation-based assessment that lasts for 30 minutes. In this section, candidates are presented with 6 simulations that simulate real-world scenarios they may encounter while working with Dell PowerEdge Server products. Candidates are expected to apply their knowledge and skills to troubleshoot and resolve these simulated issues. To successfully pass this section, candidates must achieve a minimum score of 66%.

Exam Topics

Server Portfolio and Features (10%)

• Define chassis form factors and numbering nomenclature
• Identify sever features and specifications
• Position the server in the market landscape

Server Components (26%)

• Define the different processor, memory options, and memory configurations
• Identify power options and redundancy features, thermal features, and liquid cooling
• Explain how expansion cards are connected and the features of the GPU, NDC, LOM, and OCP options
• Define storage options, Drives, PERC, IDSDM, and BOSS
• Analyze server security features

Server Management and Configuration Tools (14%)

• Define the function of the iDRAC, login procedures, licensing, and connection methods
• Explain the management interface options - LCC, racadm, OMSA, iSM, OME
• Define in-band and OOB management and at-the-box-management

System Administration (18%)

• Verify health status and iDRAC license
• Configure BIOS, Storage, virtual media, networking, user access, lockdown mode and group management

Server Troubleshooting (32%)

• Analyze the visual indicators on server components - system ID, PSU, and BLINK
• Explain Easy Restore, diagnostic utilities, and hardware diagnostic options
• Export an SCP file and run a log collection
• Explain Configuration Validation, crash capture, and minimum to POST
• Explain the server logs and memory error

How To Best Prepare for D-PE-OE-23 Dell PowerEdge Operate 2023 Exam?

To best prepare for the D-PE-OE-23 Dell PowerEdge Operate 2023 Exam, candidates should follow these recommended steps:
1. Review the exam objectives and syllabus provided by Dell to understand the topics and skills that will be assessed. It is important to have a clear understanding of what will be covered in the exam in order to focus your study efforts effectively.
2. Study the official Dell PowerEdge Server documentation, including installation guides, user manuals, and technical whitepapers. These resources provide comprehensive information about the Dell PowerEdge Server products and their functionalities. By studying these materials, you can gain a deep understanding of the product features, configurations, and maintenance procedures.
3. Practice hands-on experience with Dell PowerEdge Server products by setting up a lab environment or using virtualization software. Hands-on experience is crucial for gaining confidence and proficiency in working with Dell PowerEdge Server products. By setting up a lab environment or using virtualization software, you can experiment with different configurations, troubleshoot issues, and get familiar with the product interface.
4. Take advantage of practice exams and sample questions to familiarize yourself with the exam format and assess your knowledge. Practice exams and sample questions provide an opportunity to simulate the actual exam experience. By answering these questions, you can identify your strengths and weaknesses, and focus your study efforts on areas that need improvement.
5. Join online forums and communities to engage with other exam takers and industry professionals for valuable insights and study tips. Online forums and communities provide a platform for discussion and knowledge sharing. By participating in these communities, you can exchange ideas, ask questions, and learn from the experiences of others who have taken the exam or work in the industry.

View Online Dell PowerEdge Operate 2023 D-PE-OE-23 Free Questions

1. A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU. Which redundancy options does this configuration supply?
A. PSU redundancy only
B. PSU redundancy and PDU redundancy
C. No redundancy unless each PSU is connected to a separate PDU
D. PSU redundancy and Grid redundancy
Answer: A
 
2. A technician needs to configure a server to allow the OS to manipulate processor frequencies for higher power efficiency. Which setting can they enable to achieve this?
A. Logical Processing
B. Performance per Watt (DAPC.
C. Adjacent Cache Line Prefetch
D. Performance per Watt (OS)
Answer: D
 
3. A technician is replacing a fan on a mission critical PowerEdge R740 server that needs to stay operational. The server has no LCD. How can the technician determine which fan needs to be replaced?
A. Run embedded diagnostics to locate the failing fan
B. Access the Lifecycle Controller, navigate to the System > Cooling section to locate the failing fan number
C. Remove the chassis cover and observe a fan with an amber LED
D. Use the iDRAC GUI to locate failing fan number
Answer: D
 
4. How can a system administrator compare the currently installed hardware to the original system configuration?
A. Pull a SupportAssist Collection Comparison Report
B. Restore the original System Profile
C. View Factory Shipped Inventory
D. Export a Tech Support Report
Answer: C
 
5. A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.
What method can be used to enable the default login account?
A. Run the racadm racreset command from the host OS
B. Boot to F2 and select iDRAC Settings > Reset iDRAC configurations to defaults all
C. Hold down the i button for 16 seconds
D. SSH into the iDRAC and run the racadm racreset command
Answer: B
 
6. A new Dell customer is ordering servers that have very specific firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to accomplish this goal?
A. Enable the Collect System Inventory On Restart (CSIOR) attribute
B. Enable the Match Firmware of Replaced Part setting in the system BIOS
C. Configure servers to access the remote firmware repository
D. Install and configure a repository manager
Answer: A
 
7. A technician is deploying a server. What should they do once the server is fully configured and deployed?
A. Switch on write-protect for the vFlash SD card
B. Back up the server profile and reset the iDRAC to Default Settings
C. Back up the server profile and configure the Parts Replacement feature
D. Change the iDRAC secure password based on the users’ company policies
Answer: D
 
8. A technician installs a NIC on a single CPU server. However, the NIC is not detected when they power on the server. What should the technician verify to make sure that the NIC is detected correctly?
A. NIC driver is up to date
B. System Setup is set to BIOS boot mode
C. NIC is installed in an expansion slot managed by the single CPU
D. Network cable is plugged into the newly installed NIC
Answer: C
 
9. What is required to use the Quick Sync 2 feature?
A. OpenManage Mobile app
B. Type A/A USB cable
C. NFC
D. Ethernet connection to iDRAC NIC
Answer: A
 
10. A technician wants to configure the iDRAC on a new server using the iDRAC Quick Sync 2 feature. What is required to use this feature?
A. OpenManage Mobile App installed on an Android or iOS device
B. OpenManage Mobile App installed on a laptop
C. Quick Sync enabled bezel
D. iDRAC Enterprise license
Answer: A